Electronic Product Design, Inc.
Electronic Product Designers including our own line: Power
Meter, Wattmeter, Kilo Watt Meter Design and Manufacturer.
Power measurement, Watts and Watt Hours. Energy Meters measuring
Watts, watthours and Kilo Watthours. Energy Star/Blue Angel
wattmeters and Power Meters. Single Phase and 3 Phase Wattmeters,
Power Meters and Watthour meters.
Custom Design by Electronic Product Design, Inc.
Prototyping.
We will design and build your working prototype and provide
complete schematics and parts list as well as layouts for
printed circuit boards.
One of a kind designs.
In support of your objectives we can design and build support
apparatus: for example, recently we built a matrix switching
device for use as input to a grant supported, virtual reality
platform.
Grant support.
We can be your first phase electronic engineering company.
We can also help with subsequent phases into production.
Parts, manufacturing, and production support.
We can establish inroads for parts procurement, vendor net
30 accounts, and production services.
Custom design of our own products.
What exactly do you need? Let us know and we will provide
it just like you want it. From form to function our equipment
can be modified and adapted to meet your requirements.
Private labeling.
Protect and identify your investment by having our equipment
bear your name and logo. This service can often be uitlized
on even a single quantity purchase. Loggers, Alarms and
Other Equipment
Select the Equipment you are interested in:
Logging Time Meters
These Logging Time Meters record the amount of time an electrical
device is on. Infrared technology is used to transmit data
to a handheld reader for subsequent transfer to a computer
serial port . Eliminates redundent manhours and mistakes
copying and entering data.
UDL
This Universal Data Logger allows logging of serial data
into one mega-byte of storage. Allows data to be presented
to spreadsheet programs for load analysis. Maskable and
multiple interval selection.
LOGGING TIME METERS
Time of use.
Infrared transmission of data.
LTM-OIR Optical detector for lighting applications. High
ambient light imunity
LTM-MIR Magnetic detector for use with zip cords, wires
behind walls, and motors.
LTM-HR Handheld infrared reader used to gather, display,
and store data for transport to office computer.
Easy to install, Easy to use.
These Light Time Meters (LTMs) are instruments designed
to record the amount of time an electrical device is turned
on. An LTM uses lithium batteries to supply operating power
for 3 years. Time is accumulated with a resolution of one
second and passed, along with a 4 digit identification number,
to handheld readers via infrared transmission.
The hand-held reader then conditions the time for display
in the desired format of XXXXX.X, giving hours and tenths
of hours. The LTMs are non-resetable and all weigh less
than 4 ounces. A visual red LED and an infrared transmitter
are integral parts of each LTM
UDL
The UDL(Universal Data Logger) is a portable, one-megabyte
memory, storage device that records input data from up to
two RS232 transmitting devices. Recorded data can then be
downloaded to a computer file for subsequent viewing or
for input into a spreadsheet program. The UDL is self contained
and programmable from its' own front panel.
The UDL filters the incoming data, records the data at programmable
time intervals, then Time/Date stamps the record event.
The UDL has the ability to filter out selected fields of
incoming data as instructed by a user-programmable mask.
The mask also allows for definition of input field delimiters.
The user also sets up the desired interval for logging.
This allows the user to log only the data fields needed
at a desired interval thereby conserving memory and reducing
the overall size of a file.
Primary power is provided by a 120-volt
AC to 12VDC adaptor. Supplemental power is provided by four
AA batteries.
Specifications
Memory.
One megabyte
UDL to computer interface.
Terminal program capable of receiving ASCII data thtough
RS232 port.
Data rate to logger.
1200, 2400, 4800, 9600, 19.2K baud rates.
Battery life.
Variable depending on recording interval and transmitting
device output frequency.Power Meters
Return to Home Page
Select the meter you are interested in:
GREENSTAR
This single phase GreenStar Volt-Amp-Watt meter is engineered
to meet the testing conditions for Energy Star measurement
of Personal Computers and Monitors.
BLUESTAR VAW-1LP
This single phase BlueStar Volt-Amp-Watt meter is engineered
to meet the testing conditions for Blue Angel power measurement
for Standby Power, 120 volt, .01 Watt resolution.
BLUESTAR VAW-2LP
This single phase BlueStar Volt-Amp-Watt meter is engineered
to meet the testing conditions for Blue Angel power measurement
for Standby Power, 280 volt, .01 Watt resolution.
STANDBY PLM-1LP
This single phase STANDBY full featured , automatic, easy
to use meter is engineered to meet the testing conditions
for STANDBY power measurement. 120 volt, .01 Watt resolution,
.001 Watt-Hour resolution.
STANDBY PLM-2LP
This single phase STANDBY full featured , automatic, easy
to use meter is engineered to meet the testing conditions
for STANDBY power measurement. 280 volt, .01 Watt resolution,
.001 Watt-Hour resolution.
EM-0
This single phase, economical, Energy Meter measures watts
and watt-hours for a standard 120 volt outlet load. This
device is essentially an extension cord with an integral
power meter.
EM-1
This single phase, precision, Energy Meter measures watts
and watt-hours for a standard 120 volt outlet load. Includes
a front panel 120 volt outlet.
EM-2
This single phase Energy Meter measures watts and watt-hours
for applications up to 280 volts RMS and 30 amps. Wired
via a rear panel terminal strip.
KW-200
This Single/Split phase Power Meter can measure one or two
phases of current referenced to a single voltage. Provides
KiloWatts and KiloWatt Hours. Indoor/Outdoor Sub-Metering,
up to 480 volts, 400 amps.
KW-1A
This Portable Single phase Power Meter provides RMS Voltage,
RMS Current, KVolt-Amps, Power-Factor, KiloWatts and KiloWatt
Hours. Up to 480 volts, 800 amps.
VAW-1
This single phase Volt-Amp-Watt Meter is designed for 120
volt applications and includes a front panel 120 volt, 15
amp outlet.
VAW-2
This single phase Volt-Amp-Watt Meter is designed for applications
up to 280 volts RMS and currents to 30 amps. Wired via a
rear panel terminal strip .
PLM-1
This single phase Power Line Meter is safe, easy to use,
accurate, and covers a full range of measurements for a
standard 120 volt, 15 amp style power outlet. The 120 volt
outlet is integral to the front panel.
PLM-2
This single phase Power Line Meter provides a full range
of measurements with voltages to 280 volts and currents
up to 30 amps. Wired via a rear panel terminal strip.
PK-VIP-1
This single phase Peak Voltage-Current-Power meter provides
peaks and crest-factor, as well as standard measurements
for 120 volt applications.
PK-VIP-2
This single phase Peak Voltage-Current-Power meter provides
peaks and crest-factor, as well as standard measurements
for applications up to 280 volts and 30 amps.
2EM
This Two Phase Energy Meter measures watts and watt-hours
for two identical isolated channels. Can be used with balanced
or unbalanced loads. Rear panel terminal strips for connecting.
PK-VIP-CT
Single phase Peak Voltage-Current-Power meter uses a current
transformer (CT) to measure a full range of parameters with
currents up to 1000 amps and voltages to 600 volts.
PK-VIP-3P
This Peak Voltage-Current-Power meter provides a full range
of measurements for 3 phase applications including delta
and wye configurations. Covers voltages up to 600 volts
and currents to 1000 amps.
DMND-3P
This Demand meter provides Peak Demand measurements for
3 phase applications including delta and wye configurations.
Real Time clock reports Date and Time of the Peak Demand
Event. Covers voltages up to 600 volts and currents to 1000
amps.
UDL
This Universal Data Logger allows logging of serial data
into one mega-byte of storage. Allows data to be presented
to spreadsheet programs for load analysis. Maskable and
multiple interval selection.
EM-0
EM-0 Picture
Maximum Current is 15 amps, RMS.
Maximum Voltage is 140 volts, RMS.
Output via alpha-numeric liquid crystal display.
Shunt style measurement. Shunt value is .01 ohms.
Operating power is 120 volts. Power consumption is 1.5 watts.
Measurement Range Accuracy
Real Power (KWatts) 1 to 2.100 1.5%+1 LSD
KW-Hours 1 to 99,999.999 1.5%+1 LSD
EM-1
EM-1 Picture
Output via alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .01 ohms.
Operating power is 120 volts. Power consumption is 1.5 watts.
Bench-Top enclosure size is 8X6X2.5 inches. Weight is one
pound.
Watt hours stored in non-volatile RAM if power is lost.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
Real Power (Watts) 1 to 2100 .5%+1 LSD
Watt-Hours 1 to 9,999,999.99 .5%+1 LSD
EM-2
Output via alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .005 ohms.
Operating power is 120 or 240 volts. Select when ordering.
Power consumption is 1.5 watts.
Bench-Top enclosure size is 8X6X4 inches. Weight is two
pounds.
Watt hours stored in non-volatile RAM if power is lost.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
Real Power (Watts) 1 to 8400 .5%+1 LSD
Watt-Hours 1 to 999,999,999 .5%+1 LSD
KW-200
KW-200 Picture
Indoor/Outdoor Sub-metering.
UP to 400 amps RMS, 800 amps peak.
Up to 480 volts RMS, 800 volts peak.
Toroid Current Transformer(CT) style measurement. Ratio
is 2000:1.
Output via alpha-numeric liquid crystal display or Infrared.
RS232 option available.
Logging capability.
Operating power is 120 or 240 volts. Select when ordering.
Power consumption is 2.5 watts.
KiloWatt hours stored in non-volatile memory if power is
lost.
Toroid CT can be installed either inside of outside of enclosure.
Size is 8 X 8 X 4 inches.
Measurement Range Accuracy
Real Power (KiloWatts) .01 to 400.00 .5%+1 LSD
KiloWatt Hours .1 to 9999999.9 .5%+1 LSD
KW-1A
KW-1A Picture
Portable Test Equipment for Single Phase Power Monitoring.
Integral Case design.
UP to 800 amps RMS, 1600 amps peak.
Up to 480 volts RMS, 800 volts peak.
Clamp-on Current Transformer(CT) style measurement. Ratio
is 1000:1.
Output via alpha-numeric liquid crystal .
RS232 option available.
Logging capability.
Operating power is 120 volts.
Power consumption is 2.5 watts.
KiloWatt hours stored in non-volatile memory if power is
lost.
Size is 8 X 8 X 4 inches.
Measurement Range Accuracy
Real Power (KiloWatts) .01 to 400.00 .5%+1 LSD
KiloWatt Hours .1 to 9999999.9 .5%+1 LSD
RMS Current .5 to 800.0 amps .5%+1 LSD
RMS Voltage 5.0 to 550.0 volts .5%+1 LSD
KVolt Amps .01 to 400.00 KVA 1%+1 LSD
Power Factor .05 to 1.00 1%+1 LSD
GREENSTAR
Meets testing conditions for Energy Star measurement of
Personal Computers and Monitors.
Current crest-factor is 10 to 1, at 1 amp, 10 amps peak.
Bandpass to the 100th harmonic of 60 hertz.
.1 watt resolution and .5% accuracy.
Output via alpha-numeric liquid crystal display.
Custom options.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .1 ohms.
Operating power is 120 or 240 volts. Select when ordering.
Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X4 inches. Weight is two pounds.
Measurement Range Accuracy
RMS Voltage .1 to 280.0 volts .5%+1 LSD
RMS Current .001 to 3.000 amps .5%+1 LSD
Real Power (Watts) .1 to 840.0 .5%+1 LSD
BLUESTAR VAW-1LP
Meets testing conditions for Blue Angel measurement of Personal
Computers and Monitors.
Current crest-factor is 10 to 1, at 1 amp, 10 amps peak.
Bandpass to the 100th harmonic of 60 hertz.
.01 watt resolution and .5% accuracy.
Output via alpha-numeric liquid crystal display.
Custom options.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .1 ohms.
Operating power is 120 volts.
Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X2.5 inches. Weight is two pounds.
Measurement Range Accuracy
RMS Voltage .1 to 140.0 volts .5%+1 LSD
RMS Current .001 to 2.000 amps .5%+1 LSD
Real Power (Watts) .01 to 280.00 .5%+1 LSD
BLUESTAR VAW-2LP
Meets testing conditions for Blue Angel measurement of Personal
Computers and Monitors.
Current crest-factor is 10 to 1, at 1 amp, 10 amps peak.
Bandpass to the 100th harmonic of 60 hertz.
.01 watt resolution and .5% accuracy.
Output via alpha-numeric liquid crystal display.
Custom options.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .1 ohms.
Operating power is 120 or 240 volts, Select when ordering.
Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X4 inches. Weight is two pounds.
Measurement Range Accuracy
RMS Voltage .1 to 280.0 volts .5%+1 LSD
RMS Current .001 to 2.000 amps .5%+1 LSD
Real Power (Watts) .01 to 560.00 .5%+1 LSD
STANDBY PLM-1LP
Meets testing conditions for Standby-Power measurement.
Easy to use in 120 volt applications.
Current crest-factor is 5 to 1, at 2 amps, 10 amps peak.
Bandpass to the 100th harmonic of 60 hertz.
.01 watt resolution and .5% accuracy.
.001 watt-hour resolution and .5% accuracy.
Output via alpha-numeric liquid crystal display.
Time Averaged Watts. .01 Watt resolution.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .1 ohms.
Operating power is 120 volts.
Bench-Top enclosure size 8X6X2.5 inches. Weight is two pounds.
Measurement Range Accuracy
RMS Voltage .1 to 140.0 volts .5%+1 LSD
RMS Current .0010 to 4.0000 amps .5%+1 LSD
Volt-Amps .01 to 560.00 1%+1 LCD
Real Power (Watts) .01 to 560.00 .5%+1 LSD
Time Averaged Watts .01 to 560.00 .5%+1 LSD
Peak Voltage .1 to 200.0 volts .5%+1 LSD
Peak Current .10 to 10.00 amps .5%+1 LSD
Peak Power (Watts) 1 to 2,000 .5%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Watt-Hours 0 to 999,999.999 .5%+1 LSD
Hours .01 to 600.00 Hours .01%+1 LSD
STANDBY PLM-2LP
Meets testing conditions for Standby-Power measurement.
Use in applications up to 280 volts.
Current crest-factor is 5 to 1, at 2 amps, 10 amps peak.
Bandpass to the 100th harmonic of 60 hertz.
.01 watt resolution and .5% accuracy.
.001 watt-hour resolution and .5% accuracy.
Time Averaged Watts. .01 Watt resolution.
Output via alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .1 ohms.
Operating power is selected when ordering. Select either
120 or 240 volts.
Bench-Top enclosure size 8X6X4 inches. Weight is two pounds.
Measurement Range Accuracy
RMS Voltage .1 to 280.0 volts .5%+1 LSD
RMS Current .0010 to 2.0000 amps .5%+1 LSD
Volt-Amps .01 to 560.00 1%+1 LCD
Real Power (Watts) .01 to 560.00 .5%+1 LSD
Time Averaged Watts .01 to 560.00 .5%+1 LSD
Peak Voltage .1 to 400.0 volts .5%+1 LSD
Peak Current .10 to 10.00 amps .5%+1 LSD
Peak Power (Watts) 1 to 2,000 .5%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Watt-Hours 0 to 999,999.999 .5%+1 LSD
Hours .01 to 600.00 Hours .01%+1 LSD
VAW-1
Output via alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .01 ohms.
Operating power is 120 volts. Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X2.5 inches. Weight is two pounds.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
RMS Voltage .1 to 140.0 volts .5%+1 LSD
RMS Current .01 to 15.00 amps .5%+1 LSD
Real Power (Watts) 1 to 2100 .5%+1 LSD
VAW-2
VAW-2 Picture
Output via alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .005 ohms.
Operating power is 120 or 240 volts. Select when ordering.
Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X4 inches. Weight is two pounds.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
RMS Voltage .1 to 280.0 volts .5%+1 LSD
RMS Current .01 to 30.00 amps .5%+1 LSD
Real Power (Watts) 1 to 8400 .5%+1 LSD
PLM-1
PLM1 Picture
Output via dual-line, alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .01 ohms.
Operating power is 120 volts. Power consumption is 1.5 watts.
Watt hours stored in non-volatile RAM if power is lost.
Bench-Top enclosure size 8X6X2.5 inches. Weight is two pounds.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
RMS Voltage .1 to 140.0 volts .5%+1 LSD
RMS Current .001 to 15.000 amps .5%+1 LSD
Volt-Amps .1 to 2100.0 1%+1 LSD
Real Power (Watts) .1 to 2800.0 .5%+1 LSD
Peak Voltage .1 to 200.0 volts .5%+1 LSD
Peak Current .1 to 100.0 amps .5%+1 LSD
Peak Power (Watts) 1 to 20,000 .5%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Watt-Hours 1 to 9,999,999.99 .5%+1 LSD
Hours .01 to 655.36 Hours .01%+1 LSD
PLM-2
PLM2 Picture
Output via dual-line, alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .005 ohms.
Operating power is 120 volts or 240 volts. Select when ordering.
Power consumption is 1.5 watts.
Watt hours stored in non-volatile RAM if power is lost.
Bench-Top enclosure size 8X6X4 inches. Weight is two pounds.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
RMS Voltage .1 to 280.0 volts .5%+1 LSD
RMS Current .01 to 30.000 amps .5%+1 LSD
Volt-Amps .1 to 8400.0 1%+1 LSD
Real Power (Watts) .1 to 8400.0 .5%+1 LSD
Peak Voltage .1 to 400.0 volts .5%+1 LSD
Peak Current .1 to 200.0 amps .5%+1 LSD
Peak Power (Watts) 1 to 80,000 .5%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Watt-Hours 1 to 9,999,999.99 .5%+1 LSD
Hours .01 to 655.36 Hours .01%+1 LSD
PK-VIP-1
Output via dual-line, alpha-numeric liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .01 ohms.
Operating power is 120 volts. Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X2.5 inches. Weight is two pounds.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
RMS Voltage .1 to 140.0 volts .5%+1 LSD
RMS Current .01 to 20.00 amps .5%+1 LSD
Volt-Amps 1 to 2800 1%+1 LSD
Real Power (Watts) 1 to 2800 .5%+1 LSD
Peak Voltage .1 to 200.0 volts .5%+1 LSD
Peak Current .1 to 100.0 amps .5%+1 LSD
Peak Power (Watts) 1 to 20,000 .5%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Current Crest Factor .01 to 10.00 1%+1 LSD
PK-VIP-2
PEAK VIP-2 Picture
Output via dual-line, twenty char. per line, alpha-numeric
liquid crystal display.
RS232 option available.
Logging capability.
Shunt style measurement. Shunt value is .005 ohms.
Operating power is 120 volts or 240 volts. Select when ordering.
Power consumption is 1.5 watts.
Bench-Top enclosure size 8X6X4 inches. Weight is two pounds.
Current crest-factor is 6 to 1, worst case.
Measurement Range Accuracy
RMS Voltage .1 to 280.0 volts .5%+1 LSD
RMS Current .01 to 30.00 amps .5%+1 LSD
Volt-Amps 1 to 8400 1%+1 LSD
Real Power (Watts) 1 to 8400 .5%+1 LSD
Peak Voltage .1 to 400.0 volts .5%+1 LSD
Peak Current .1 to 200.0 amps .5%+1 LSD
Peak Power (Watts) 1 to 80,000 .5%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Current Crest Factor .01 to 10.00 1%+1 LSD
2EM
2EM Picture
Output via alpha-numeric liquid crystal display.
Two identical isolated channels.
Balanced or unbalanced loads.
Shunt style measurement. Shunt value is .005 ohms.
Operating power is 120 or 240 volts. Select when ordering.
Power consumption is 3.5 watts.
Bench-Top enclosure size 10X10X4 inches. Weight is four
pounds.
Watt hours stored in non-volatile RAM if power is lost.
Current crest-factor is 6 to 1, worst case.
Measurement per channel Range Accuracy
Real Power (Watts) 1 to 8400 .5%+1 LSD
Watt-Hours 1 to 999,999,999 .5%+1 LSD
PK-VIP-CT
Peak VIP-CT Picture
Output via liquid crystal display.
Output via RS232 port. Unidirectional, 9600 baud.
Logging capability.
Available as stand alone board or in bench-top enclosure
or in NEMA4 case.
Portable or permanent mounting.
Application: Portable or permanent measurement
of power parameters from 25, 50, 60, or 400 hz power lines.
Power consumption: 4 watts.
Current input: Current transformer. Ratio is 1000 to 1.
Voltage Input: 1 to 1 ratio. Direct connection and readout.
Bandpass: 100th harmonic of 60 hz. (6khz).
Isolation: 1500 volts between the four isolated circuits
of voltage, current, input-power, RS232 and pulse circuit.
Accuracy specifications do not include
errors of Current Transformers (CTs).
Measurement Range Accuracy
RMS Voltage .1 to 600.0 volts .25%+1 LSD
RMS Current .1 to 1000 amps .25%+1 LSD
Volt-Amps .01 to 600.00 KVA .5%+1 LSD
Real Power (Watts) .01 to 600.00 KW .5%+1 LSD
Peak Voltage .1 to 1000 volts 1%+1 LSD
Peak Current .1 to 2000 amps 1%+1 LSD
Peak Power (Watts) .1 to 2000.0 KW 1%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Kilo-VARS .01 to 600.00KVARS 1.5%+1 LSD
Accumulate Power .01 to 9999999.99 KWH
.5%+1 LSD
Kilo-Watt Hours
or KiloVA-Hours
or KiloVARS-Hours
or HI KWDMND 15M Avg.
PK-VIP-3P
Peak VIP-3P Picture
Three Phase, Delta or Wye.
Logging capability.
Single and multi-phase readings.
Output via liquid crystal display.
Output via RS232 port. Unidirectional, 9600 baud.
Available as stand alone board or in bench-top enclosure
or in NEMA4 case.
Portable or permanent mounting.
Application: Portable or permanent measurement
of power parameters from 25, 50, 60, or 400 hz power lines.
Power consumption: 4 watts.
Current input: Current transformer. Ratio is 1000 to 1.
Voltage Input: 1 to 1 ratio. Direct connection and readout.
Bandpass: 100th harmonic of 60 hz. (6khz).
Isolation: 1500 volts between the four isolated circuits
of voltage, current, input-power, RS232 and pulse circuit.
Accuracy specifications do not include
errors of Current Transformers (CTs).
Specification per Phase
Measurement Range Accuracy
RMS Voltage .1 to 600.0 volts .25%+1 LSD
RMS Current .1 to 1000 amps .25%+1 LSD
Volt-Amps .01 to 600.00 KVA .5%+1 LSD
Real Power (Watts) .01 to 600.00 KW .5%+1 LSD
Peak Voltage .1 to 1000 volts 1%+1 LSD
Peak Current .1 to 2000 amps 1%+1 LSD
Peak Power (Watts) .1 to 2000.0 KW 1%+1 LSD
Power Factor .01 to 1.00 1.5%+1 LSD
Kilo-VARS .01 to 600.00KVARS 1.5%+1 LSD
Totalized Readouts
Measurement Range Accuracy
Accumulated Power (KW-H, KVA-H, KVARS-H) .01 to 9999999.00
KW-Hours .5%+1 LSD
Power .01 to 1800.00 KW .5%+1 LSD
KVA .01 to 1800 KVA .5%+1 LSD
Power factor .01 to 1.00 1%+1 LSD
DMND-3P
Three Phase, Delta or Wye.
Demand Interval variable between 5 and 30 minutes at 5 minute
increments.
Logging capability.
Single and multi-phase readings.
Output via liquid crystal display.
Output via RS232 port. Unidirectional, 9600 baud.
Available as stand alone board or in bench-top enclosure
or in NEMA4 case.
Portable or permanent mounting.
Application: Portable or permanent measurement
of Demand parameters from 25, 50, 60, or 400 hz power lines.
Power consumption: 4 watts.
Current input: Current transformer. Ratio is 1000 to 1.
Voltage Input: 1 to 1 ratio. Direct connection and readout.
Bandpass: 100th harmonic of 60 hz. (6khz).
Isolation: 1500 volts between the four isolated circuits
of voltage, current, input-power, RS232 and pulse circuit.
Accuracy specifications do not include
errors of Current Transformers (CTs).
Specification per Phase
Measurement Range Accuracy
RMS Voltage .1 to 600.0 volts .25%+1 LSD
RMS Current .1 to 1000 amps .25%+1 LSD
Totalized Readouts
Measurement Range Accuracy
Accumulated Power .01 to 9999999.00 KW-Hours .5%+1 LSD
Power .01 to 1800.00 KW .5%+1 LSD
KVA .01 to 1800 KVA .5%+1 LSD
Power factor .01 to 1.00 1%+1 LSD
Accumulated Time .00 to 99,999,00 Hours .05%
Demand Functions
Measurement Range Accuracy
Peak Demand .01 to 1800.00 KW-Hours .5%+1 LSD
Peak Date Month/Day/Year
Peak Time Hours:Minutes 24 Hour clock
UDL
UDL Picture
The UDL(Universal Data Logger) is a portable, one-megabyte
memory, storage device that records input data from up to
two RS232 transmitting devices. Recorded data can then be
downloaded to a computer file for subsequent viewing or
for input into a spreadsheet program. The UDL is self contained
and programmable from its' own front panel.
The UDL filters the incoming data, records the data at programmable
time intervals, then Time/Date stamps the record event.
The UDL has the ability to filter out selected fields of
incoming data as instructed by a user-programmable mask.
The mask also allows for definition of input field delimiters.
The user also sets up the desired interval for logging.
This allows the user to log only the data fields needed
at a desired interval thereby conserving memory and reducing
the overall size of a file.
Primary power is provided by a 120-volt
AC to 12VDC adaptor. Supplemental power is provided by four
AA batteries.
Specifications
Memory.
One megabyte
UDL to computer interface.
Terminal program capable of receiving ASCII data thtough
RS232 port.
Data rate to logger.
1200, 2400, 4800, 9600, 19.2K baud rates.
Battery life.
Variable depending on recording interval and transmitting
device output frequency.